- Date
- 06/03/2020
- W/O
- 833634
- Weather
- Dry
- Operator/Surveyor
- EN. RUIZ
- Sewer ID
- Z00259
- PipeID
- P02671
- Time
- 10:27 PM
- Certificate
- U-116-07001919
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K7759
- Sewer Name
- EAST COMPTON BOULEVARD RELIEF TRUNK
- City
- BELLFLOWER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 33
- Purpose
- Routine Assessment
- Project
- RFIR_WO_833634_TV02385_JUN2020
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- 02 0357
- Downstream MH
- 02 0356
- Dir. of Survey
- Downstream
- Length Surveyed
- 289.4 ft.
- Total Length
- 289.4 ft.
- Structural Index
- 3
- Structural Quick
- 423J
- Structural Rating
- 293
- O&M Index
- 3
- O&M Quick
- 3J2E
- O&M Rating
- 235
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 528
Pipe schematic from manhole 02 0357 to 02 0356 Observation photos (4)

2.1 ft. - Deposits Settled Other, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Start - UNKNOWN

58.7 ft. - Fracture Multiple, from 03 to 07 o'clock, within 8 inches of joint: YES

124.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Start

162.8 ft. - Fracture Multiple, from 04 to 09 o'clock, within 8 inches of joint: YES