- Date
- 06/04/2020
- W/O
- 833634
- Weather
- Dry
- Operator/Surveyor
- EN. RUIZ
- Sewer ID
- Z00259
- PipeID
- P02666
- Time
- 9:06 PM
- Certificate
- U-116-07001919
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K7760
- Sewer Name
- EAST COMPTON BOULEVARD RELIEF TRUNK
- City
- BELLFLOWER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 33
- Purpose
- Routine Assessment
- Project
- RFIR_WO_833634_TV02385_JUN2020
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- 02 0352
- Downstream MH
- 02 0351
- Dir. of Survey
- Downstream
- Length Surveyed
- 389.5 ft.
- Total Length
- 389.5 ft.
- Structural Index
- 3
- Structural Quick
- 423N
- Structural Rating
- 393
- O&M Index
- 1
- O&M Quick
- 221C
- O&M Rating
- 24
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 417
Pipe schematic from manhole 02 0352 to 02 0351 Observation photos (4)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Start

2 ft. - Roots Fine Joint, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

4.1 ft. - Fracture Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES

372.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES