Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 5, 2020, 09:08 AM
  • 02 0340_02 0339_06052020_025215.mp4

Date
06/05/2020
W/O
833634
Weather
Dry
Operator/Surveyor
EN. RUIZ
Sewer ID
Z00259
PipeID
P02651
Time
2:08 AM
Certificate
U-116-07001919
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7760
Sewer Name
EAST COMPTON BOULEVARD RELIEF TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
37
Purpose
Routine Assessment
Project
RFIR_WO_833634_TV02385_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
18 in.
Upstream MH
02 0340
Downstream MH
02 0339
Dir. of Survey
Downstream
Length Surveyed
326.3 ft.
Total Length
326.3 ft.
Structural Index
3
Structural Quick
443L
Structural Rating
336
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
340
Pipe schematic from manhole 02 0340 to 02 0339
MH: 02 0340MH: 02 0339downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - ROACHES @ MH0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE0 ft. AMH - Upstream Manhole, Survey Begins - 02 03400 ft. MWL - Water Level, 15 %of cross sectional area2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Start19.2 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES65.2 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES142.4 ft. FM - Fracture Multiple, from 09 to 11 o'clock, within 8 inches of joint: YES218.7 ft. FM - Fracture Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES322.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Finish324 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish324 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish326.3 ft. AMH - Downstream Manhole, Survey Ends - 02 0339

Observation photos (6)

  • General Observation - ROACHES @ MH

    0 ft. - General Observation - ROACHES @ MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: NO, Start

    2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Start

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    19.2 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    65.2 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 11 o'clock, within 8 inches of joint: YES

    142.4 ft. - Fracture Multiple, from 09 to 11 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES

    218.7 ft. - Fracture Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
2.1DAGS
322.7DAGS
19.2FM
324CM
324SSS
2CM
0MWM
142.4FM
0MGOROACHES @ MH
65.2FM
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
0AMH02 0340
326.3AMH02 0339
0MWL
2SSS
218.7FM

Properties (7)

additional_info
SC411468
custom_field_three
FRACTURES, GREASE
custom_field_two
3
customer
1
datetime
2020-06-05T02:08:48-07:00
documentation
PRO PIPE
is_lateral_inspection
false