Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 18, 2020, 07:00 AM
  • 02 0334_02 0333_06182020_001310.mp4

Date
06/18/2020
W/O
833634
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00259
PipeID
P02645
Time
12:00 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7733
Sewer Name
EAST COMPTON BOULEVARD RELIEF TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
37
Purpose
Routine Assessment
Project
RFIR_WO_833634_TV02385_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
18 in.
Upstream MH
02 0333
Downstream MH
02 0334
Dir. of Survey
Upstream
Length Surveyed
400.4 ft.
Total Length
400.4 ft.
Structural Index
2
Structural Quick
4333
Structural Rating
179
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
179
Pipe schematic from manhole 02 0333 to 02 0334
MH: 02 0333MH: 02 0334upstream0 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - 02 03342.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish51.3 ft. FM - Fracture Multiple, from 09 to 10 o'clock, within 8 inches of joint: YES167.8 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES214.2 ft. FM - Fracture Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES283.9 ft. FM - Fracture Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES383.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start398.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start400.4 ft. AMH - Downstream Manhole, Survey Begins - 02 0333400.4 ft. MWM - Water Mark, 30 %of cross sectional area400.4 ft. MWL - Water Level, 25 %of cross sectional area

Observation photos (6)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    16.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES

    116.5 ft. - Fracture Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES

    186.2 ft. - Fracture Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    232.6 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 10 o'clock, within 8 inches of joint: YES

    349.1 ft. - Fracture Multiple, from 09 to 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

    400.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observations (12)

DistanceCodeObservation
349.1FM
400.4CM
16.8CM
0AMH02 0333
116.5FM
232.6FL
0MWM
186.2FM
2SSS
398SSS
400.4AMH02 0334
0MWL

Properties (7)

additional_info
SC411392
custom_field_three
MULTIPLE CRACKS/ SOME FRACTURE'S
custom_field_two
3
customer
1
datetime
2020-06-18T00:00:17-07:00
documentation
PROPIPE
is_lateral_inspection
false