Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 19, 2020, 06:57 AM
  • 02 0332_02 0331_06192020_000817.mp4

Date
06/18/2020
W/O
833634
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00259
PipeID
P02643
Time
11:57 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7733
Sewer Name
EAST COMPTON BOULEVARD RELIEF TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
37
Purpose
Routine Assessment
Project
RFIR_WO_833634_TV02385_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
18 in.
Upstream MH
02 0332
Downstream MH
02 0331
Dir. of Survey
Downstream
Length Surveyed
371.6 ft.
Total Length
371.6 ft.
Structural Index
3
Structural Quick
433N
Structural Rating
240
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
242
Pipe schematic from manhole 02 0332 to 02 0331
MH: 02 0332MH: 02 0331downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 03320 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start29.6 ft. CM - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES40 ft. FM - Fracture Multiple, from 01 to 05 o'clock, within 8 inches of joint: YES50.1 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES67.9 ft. FM - Fracture Multiple, from 09 to 10 o'clock, within 8 inches of joint: YES205.9 ft. FM - Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES284.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES285.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"369 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish369.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish371.6 ft. AMH - Downstream Manhole, Survey Ends - 02 0331

Observation photos (7)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

    29.6 ft. - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 01 to 05 o'clock, within 8 inches of joint: YES

    40 ft. - Fracture Multiple, from 01 to 05 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    50.1 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 10 o'clock, within 8 inches of joint: YES

    67.9 ft. - Fracture Multiple, from 09 to 10 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

    205.9 ft. - Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

  • Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock,  , within 8 inches of joint: YES

    284.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES

Observations (15)

DistanceCodeObservation
2CM
2SSS
369SSS
369.1CM
67.9FM
371.6AMH02 0331
0MWL
40FM
205.9FM
0AMH02 0332
29.6CM
284.8DAGS
50.1CL
0MWM
285.8TFA

Properties (7)

additional_info
SC411392
custom_field_three
MULTIPLE CRACKS/SOME FRACTURE'S
custom_field_two
3
customer
1
datetime
2020-06-18T23:57:12-07:00
documentation
PROPIPE
is_lateral_inspection
false