Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 19, 2020, 07:47 AM
  • 02 0326_02 0325_06192020_010152.mp4

Date
06/19/2020
W/O
833634
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00259
PipeID
P02637
Time
12:47 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7734
Sewer Name
EAST COMPTON BOULEVARD RELIEF TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
37
Purpose
Routine Assessment
Project
RFIR_WO_833634_TV02385_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
18 in.
Upstream MH
02 0325
Downstream MH
02 0326
Dir. of Survey
Upstream
Length Surveyed
225 ft.
Total Length
225 ft.
Structural Index
3
Structural Quick
4231
Structural Rating
15
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
15
Pipe schematic from manhole 02 0325 to 02 0326
MH: 02 0325MH: 02 0326upstream0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE0 ft. AMH - Upstream Manhole, Survey Ends - 02 03262 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish75.4 ft. FM - Fracture Multiple, from 11 to 03 o'clock, within 8 inches of joint: YES166.4 ft. FM - Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES179.1 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES187 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES223 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start225 ft. MWM - Water Mark, 25 %of cross sectional area225 ft. MWL - Water Level, 20 %of cross sectional area225 ft. AMH - Downstream Manhole, Survey Begins - 02 0325

Observation photos (4)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES

    45.9 ft. - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

    58.6 ft. - Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 11 to 03 o'clock, within 8 inches of joint: YES

    149.6 ft. - Fracture Multiple, from 11 to 03 o'clock, within 8 inches of joint: YES

Observations (11)

DistanceCodeObservation
0MWM
225MGOCONN @ MH 3 O'CLOCK/ACTIVE
45.9FC
223CM
149.6FM
0MWL
225AMH02 0326
38CL
58.6FM
2CM
0AMH02 0325

Properties (7)

additional_info
SC411393
custom_field_three
MULTIPLE CRACKS/SOME FRACTURE'S
custom_field_two
3
customer
1
datetime
2020-06-19T00:47:09-07:00
documentation
PROPIPE
is_lateral_inspection
false