Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 19, 2020, 08:19 AM
  • 02 0324_02 0323_06192020_012836.mp4

Date
06/19/2020
W/O
833634
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00259
PipeID
P02635
Time
1:19 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7734
Sewer Name
EAST COMPTON BOULEVARD RELIEF TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
37
Purpose
Routine Assessment
Project
RFIR_WO_833634_TV02385_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
18 in.
Upstream MH
02 0324
Downstream MH
02 0323
Dir. of Survey
Downstream
Length Surveyed
384 ft.
Total Length
384 ft.
Structural Index
3
Structural Quick
413N
Structural Rating
378
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
378
Pipe schematic from manhole 02 0324 to 02 0323
MH: 02 0324MH: 02 0323downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 03242 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start6.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start377.7 ft. FM - Fracture Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES378.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish382 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish384 ft. AMH - Downstream Manhole, Survey Ends - 02 0323

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

    377.7 ft. - Fracture Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

Observations (9)

DistanceCodeObservation
0MWM
6.7CM
382SSS
0MWL
378.2CM
377.7FM
384AMH02 0323
2SSS
0AMH02 0324

Properties (6)

additional_info
SC411393
custom_field_two
3
customer
1
datetime
2020-06-19T01:19:21-07:00
documentation
PROPIPE
is_lateral_inspection
false