Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 19, 2020, 08:49 AM
  • 02 0323_02 0322_06192020_020020.mp4

Date
06/19/2020
W/O
833634
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00259
PipeID
P02634
Time
1:49 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7734
Sewer Name
EAST COMPTON BOULEVARD RELIEF TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
39
Purpose
Routine Assessment
Project
RFIR_WO_833634_TV02385_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
18 in.
Upstream MH
02 0323
Downstream MH
02 0322
Dir. of Survey
Downstream
Length Surveyed
414.5 ft.
Total Length
414.5 ft.
Structural Index
3
Structural Quick
423O
Structural Rating
420
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
420
Pipe schematic from manhole 02 0323 to 02 0322
MH: 02 0323MH: 02 0322downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 03232 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start3.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start43.3 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES128.9 ft. FM - Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES321.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES412 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish414.5 ft. AMH - Downstream Manhole, Survey Ends - 02 0322414.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (4)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES

    43.3 ft. - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

    128.9 ft. - Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    321.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (11)

DistanceCodeObservation
414.5AMH02 0322
321.7FM
128.9FM
412SSS
0MWM
2SSS
0MWL
0AMH02 0323
43.3FC
414.5CM
3.3CM

Properties (7)

additional_info
SC411393
custom_field_three
MULTIPLE CRACKS/SOME FRACTURE'S
custom_field_two
3
customer
1
datetime
2020-06-19T01:49:59-07:00
documentation
PROPIPE
is_lateral_inspection
false