Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 11, 2020, 07:49 AM
  • 08 0190_08 0189_06112020_005334.mp4

Date
06/11/2020
W/O
833557
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00009
PipeID
P00250
Time
12:49 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7725
Sewer Name
GRACE STREET TRUNK, SECTION 1
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
13
Purpose
Routine Assessment
Project
WO_833557_TV08019_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
12 in.
Upstream MH
08 0190
Downstream MH
08 0189
Dir. of Survey
Downstream
Length Surveyed
17 ft.
Total Length
17 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 08 0190 to 08 0189
MH: 08 0190MH: 08 0189downstream0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK CAPPED0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 01900 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK CAPPED3.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start17 ft. AMH - Downstream Manhole, Survey Ends - 08 018917 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK17 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
0MGOCONNECTION AT MH 3 O'CLOCK CAPPED
17AMH08 0189
0MWM
3.1CM
0MWL
0AMH08 0190
17MGOCONNECTION AT MH 3 O'CLOCK
0MGOCONNECTION AT MH 9 O'CLOCK CAPPED
17CM

Properties (7)

additional_info
SC411383
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-06-11T00:49:50-07:00
documentation
PROPIPE
is_lateral_inspection
false