Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 11, 2020, 06:01 AM
  • 08 0188_08 0187A_06102020_231338.mp4

Date
06/10/2020
W/O
833557
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00009
PipeID
P00248
Time
11:01 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7725
Sewer Name
GRACE STREET TRUNK, SECTION 1
City
CARSON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
13
Purpose
Routine Assessment
Project
WO_833557_TV08019_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
12 in.
Upstream MH
08 0188
Downstream MH
08 0187A
Dir. of Survey
Downstream
Length Surveyed
208.2 ft.
Total Length
208.2 ft.
Structural Index
4
Structural Quick
4F00
Structural Rating
132
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
136
Pipe schematic from manhole 08 0188 to 08 0187A
MH: 08 0188MH: 08 0187Adownstream0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 018811.5 ft. FM - Fracture Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES20.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES45.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"48.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6", 6"55 ft. FM - Fracture Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES64 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start92.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"93.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"145.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"149 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"150 ft. FM - Fracture Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES150.1 ft. IR - Infiltration Runner, from 08 to 09 o'clock, within 8 inches of joint: YES151.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"196.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"198.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"201 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"208 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish208.2 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK208.2 ft. AMH - Downstream Manhole, Survey Ends - 08 0187A

Observation photos (4)

  • Fracture Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

    11.5 ft. - Fracture Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES

    150 ft. - Fracture Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES

  • Infiltration Runner, from 08 to 09 o'clock, within 8 inches of joint: YES

    150.1 ft. - Infiltration Runner, from 08 to 09 o'clock, within 8 inches of joint: YES

  • Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    201 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

Observations (23)

DistanceCodeObservation
208.2MGOCONNECTION AT MH 3 O'CLOCK
45.2TFC
198.8TFC
196.7TFC
20.6FM
48.2TFA
150.1IR
150FM
151.7TF
0MGOCONNECTION AT MH 9 O'CLOCK
201TBA
55FM
92.5TFC
145.8TFC
0MWL
64FM
0MWM
149TFC
93.8TFA
208FM
11.5FM
0AMH08 0188
208.2AMH08 0187A

Properties (7)

additional_info
SC411383
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-06-10T23:01:09-07:00
documentation
PROPIPE
is_lateral_inspection
false