Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 11, 2020, 06:31 AM
  • 08 0187_08 0186_06102020_233907.mp4

Date
06/10/2020
W/O
833557
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00009
PipeID
P00246
Time
11:31 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7725
Sewer Name
GRACE STREET TRUNK, SECTION 1
City
CARSON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Routine Assessment
Project
WO_833557_TV08019_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
12 in.
Upstream MH
08 0187
Downstream MH
08 0186
Dir. of Survey
Downstream
Length Surveyed
125 ft.
Total Length
125 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 08 0187 to 08 0186
MH: 08 0187MH: 08 0186downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 01870 ft. MWL - Water Level, 15 %of cross sectional area3.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start19 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"21.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"64.9 ft. RFJ - Roots Fine Joint, from 09 to 04 o'clock, within 8 inches of joint: YES66.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"68.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"119.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"121.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"125 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK125 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish125 ft. AMH - Downstream Manhole, Survey Ends - 08 0186

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (14)

DistanceCodeObservation
0MWM
3.1CM
0AMH08 0187
68.7TFC
119.1TF
125MGOCONNECTION AT MH 3 O'CLOCK
0MWL
125CM
19TF
125AMH08 0186
21.8TFC
66.4TF
121.9TFC
64.9RFJ

Properties (7)

additional_info
SC411383
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-06-10T23:31:06-07:00
documentation
PROPIPE
is_lateral_inspection
false