Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 11, 2020, 09:35 AM
  • 08 0183_08 0182_06112020_024445.mp4

Date
06/11/2020
W/O
833557
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00009
PipeID
P00242
Time
2:35 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7725
Sewer Name
GRACE STREET TRUNK, SECTION 1
City
CARSON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Routine Assessment
Project
WO_833557_TV08019_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
12 in.
Upstream MH
08 0182
Downstream MH
08 0183
Dir. of Survey
Upstream
Length Surveyed
218 ft.
Total Length
218 ft.
Structural Index
3
Structural Quick
3G00
Structural Rating
126
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
128
Pipe schematic from manhole 08 0182 to 08 0183
MH: 08 0182MH: 08 0183upstream0 ft. AMH - Upstream Manhole, Survey Ends - 08 01830 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish43.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"45.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"48 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"94.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"98 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"145.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"148.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"151 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 02 to 05 o'clock, , within 8 inches of joint: YES195.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"198.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"211.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start218 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK218 ft. AMH - Downstream Manhole, Survey Begins - 08 0182218 ft. MWM - Water Mark, 25 %of cross sectional area218 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 10 %of cross sectional area, from 02 to 05 o'clock,  , within 8 inches of joint: YES

    67 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 02 to 05 o'clock, , within 8 inches of joint: YES

Observations (17)

DistanceCodeObservation
0MGOCONNECTION AT MH 3 O'CLOCK
218AMH08 0183
67DAGS
22.9TFC
174.9TF
72.7TFC
69.1TFA
170TFC
6.1CM
123.6TFC
0AMH08 0182
19.1TFC
218CM
120TFC
0MWM
0MWL
172.6TFC

Properties (7)

additional_info
SC411383
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-06-11T02:35:03-07:00
documentation
PROPIPE
is_lateral_inspection
false