Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 24, 2020, 06:27 AM
  • 15 0730_15 0729_06232020_235103.mp4

Date
06/23/2020
W/O
833482
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00616
PipeID
P12623
Time
11:27 PM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7806
Sewer Name
15 MONROVIA OUTFALL TRUNK
City
MONROVIA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
09
Purpose
Routine Assessment
Project
WO_833482_TV15132_JUN2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
15 0730
Downstream MH
15 0729
Dir. of Survey
Downstream
Length Surveyed
660.5 ft.
Total Length
660.5 ft.
Structural Index
3
Structural Quick
3Y00
Structural Rating
393
O&M Index
2
O&M Quick
2T00
O&M Rating
206
Overall Index
3
Overall Quick
Overall Rating
599
Pipe schematic from manhole 15 0730 to 15 0729
MH: 15 0730MH: 15 0729downstream0 ft. MGO - General Observation - CONNECTION IN MH, 3 O' CLOCK0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 07303.3 ft. MGO - General Observation - MAG COATING ATTATCHED3.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start141.5 ft. DSC - Deposits Settled Compacted, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start658.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish658.6 ft. DSC - Deposits Settled Compacted, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish659.9 ft. MGO - General Observation - CONNECTION IN MH, 3 O' CLOCK659.9 ft. MGO - General Observation - CONNECTION IN MH, 9 O' CLOCK660.5 ft. AMH - Downstream Manhole, Survey Ends - 15 0729

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
0MGOCONNECTION IN MH, 3 O' CLOCK
3.3MGOMAG COATING ATTATCHED
658.6SAP
660.5AMH15 0729
0MWM
659.9MGOCONNECTION IN MH, 3 O' CLOCK
141.5DSC
0MWL
0AMH15 0730
659.9MGOCONNECTION IN MH, 9 O' CLOCK
3.3SAP
658.6DSC

Properties (7)

additional_info
SC411616
custom_field_three
AGGREGATE PROJECTING
custom_field_two
3
customer
1
datetime
2020-06-23T23:27:44-07:00
documentation
PROPIPE
is_lateral_inspection
false