Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 17, 2020, 07:46 AM
  • 16 0276_16 0275_7172020_032549.mp4

Date
07/17/2020
W/O
0839269
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00652
PipeID
P13318
Time
12:46 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1487R
Sewer Name
16 CHAPEL AVENUE TRUNK, SECTION 1
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
17
Purpose
Maintenance Related
Project
20200717MDM_CHAPEL_AVENUE_TRUNK_SECTION_1
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
16 0276
Downstream MH
16 0275
Dir. of Survey
Downstream
Length Surveyed
168 ft.
Total Length
168 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
4121
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 16 0276 to 16 0275
MH: 16 0276MH: 16 0275downstream0 ft. MGO - General Observation - MH CONN 9:00 ACTIVE0 ft. MWM - Water Mark, 60 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 3:25AM0 ft. MWL - Water Level, 10 %of cross sectional area31.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open61.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 10 o'clock, , within 8 inches of joint: YES68.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open124.6 ft. MGO - General Observation - POSSIBLE CONN STUB 12:00126.1 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open168 ft. AMH - Downstream Manhole, Survey Ends - 3:35AM

Observation photos (1)

  • General Observation - POSSIBLE CONN STUB 12:00

    124.6 ft. - General Observation - POSSIBLE CONN STUB 12:00

Observations (10)

DistanceCodeObservation
68.1TFOpen
168AMH3:35AM
61.4DAGS
0MGOMH CONN 9:00 ACTIVE
126.1TBOpen
0MWM
124.6MGOPOSSIBLE CONN STUB 12:00
31.4TFOpen
0AMH3:25AM
0MWL

Properties (5)

additional_info
ROOT EVALUATION ONLY
customer
LACSD
datetime
2020-07-17T00:46:20-07:00
documentation
MARTIN,OLIVER 111,SHADLER,BARR
is_lateral_inspection
false