Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 3, 2020, 04:49 AM
  • 02 0808_02 0807_06022020_215901.mp4

Date
06/02/2020
W/O
833636
Weather
Dry
Operator/Surveyor
EN. RUIZ
Sewer ID
Z00294
PipeID
P03374
Time
9:49 PM
Certificate
U-116-07001919
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7757
Sewer Name
OLD RIVER SCHOOL ROAD TRUNK, SECTS 1&2
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
24
Purpose
Routine Assessment
Project
RFIR_WO_833636_TV02392_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
18 in.
Upstream MH
02 0808
Downstream MH
02 0807
Dir. of Survey
Downstream
Length Surveyed
317.7 ft.
Total Length
317.7 ft.
Structural Index
3
Structural Quick
4932
Structural Rating
54
O&M Index
2
O&M Quick
2K00
O&M Rating
124
Overall Index
2
Overall Quick
Overall Rating
178
Pipe schematic from manhole 02 0808 to 02 0807
MH: 02 0808MH: 02 0807downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 08082 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start2.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Start8.2 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES23.1 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES31 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish44.9 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES45 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"73 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES76 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"93.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"126.2 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES138.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"142 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"158.6 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES190 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"193.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"200 ft. FM - Fracture Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES240 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES241.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"245 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"263.6 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: NO273.8 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES291.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"295.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"309 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES313.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Finish317.7 ft. AMH - Downstream Manhole, Survey Ends - 02 0807

Observation photos (9)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: NO, Start

    2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Start

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    8.2 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    23.1 ft. - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    44.9 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    73 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    126.2 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    158.6 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: NO

    263.6 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: NO

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    273.8 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (30)

DistanceCodeObservation
200FM
313.3DAGS
31SSS
295.5TFC
45TFC
291.7TFC
263.6FM
0MWL
0MWM
76TF
240FM
2SSS
317.7AMH02 0807
142TFC
190TFC
44.9FM
93.2TFC
0AMH02 0808
193.2TFC
241.5TFC
126.2FM
8.2FM
138.8TFC
158.6FM
73FM
23.1FL
273.8FM
245TFC
309FL
2.1DAGS

Properties (7)

additional_info
SC411465
custom_field_three
FRACTURES, GREASE
custom_field_two
3
customer
1
datetime
2020-06-02T21:49:00-07:00
documentation
PRO PIPE
is_lateral_inspection
false