Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 2, 2020, 06:33 AM
  • 02 0799_02 0798_06012020_234351.mp4

Date
06/01/2020
W/O
833636
Weather
Dry
Operator/Surveyor
EN. RUIZ
Sewer ID
Z00294
PipeID
P03365
Time
11:33 PM
Certificate
U-116-07001919
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7756
Sewer Name
OLD RIVER SCHOOL ROAD TRUNK, SECTS 1&2
City
DOENEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
24
Purpose
Routine Assessment
Project
RFIR_WO_833636_TV02392_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
21 in.
Upstream MH
02 0799
Downstream MH
02 0798
Dir. of Survey
Downstream
Length Surveyed
152.4 ft.
Total Length
152.4 ft.
Structural Index
4
Structural Quick
4400
Structural Rating
16
O&M Index
2
O&M Quick
2E00
O&M Rating
58
Overall Index
2
Overall Quick
Overall Rating
74
Pipe schematic from manhole 02 0799 to 02 0798
MH: 02 0799MH: 02 0798downstream0 ft. MGO - General Observation - COCKROACHES IN MH0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH, 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 02 07990 ft. MWM - Water Mark, 20 %of cross sectional area2.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Start37.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"66.7 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES94.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES95.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"104.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"127.3 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES142.3 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES146.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"149.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Finish152.4 ft. MGO - General Observation - CONNECTION AT MH, 9 O'CLOCK152.4 ft. AMH - Downstream Manhole, Survey Ends - 02 0798152.4 ft. MGO - General Observation - COCKROACHES IN MH

Observation photos (7)

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: NO, Start

    2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Start

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    66.7 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    94.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    127.3 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    142.3 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • General Observation - COCKROACHES IN MH

    152.4 ft. - General Observation - COCKROACHES IN MH

Observations (18)

DistanceCodeObservation
95.7TFC
66.7FM
152.4MGOCONNECTION AT MH, 9 O'CLOCK
146.9TFC
152.4AMH02 0798
152.4MGOCOCKROACHES IN MH
149.4DAGS
2.1DAGS
94.4FM
0MGOCOCKROACHES IN MH
142.3FM
0MWL
127.3FM
37.9TFC
0MGOCONNECTION AT MH, 9 O'CLOCK
104.5TF
0AMH02 0799
0MWM

Properties (7)

additional_info
SC411464
custom_field_three
CRACKS, FRACTURES, GREASE
custom_field_two
3
customer
1
datetime
2020-06-01T23:33:59-07:00
documentation
PRO PIPE
is_lateral_inspection
false