Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 15, 2020, 08:33 AM
  • 18 0616_18 0615 _06152020_015040.mp4

Date
06/15/2020
W/O
833692
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00692
PipeID
P14466
Time
1:33 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7648
Sewer Name
NORTH PLANT OUTFALL RELIEF TRUNK
City
WHITTIER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_833682_TV18036_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
18 0616
Downstream MH
18 0615
Dir. of Survey
Downstream
Length Surveyed
27.4 ft.
Total Length
27.4 ft.
Structural Index
4
Structural Quick
5142
Structural Rating
19
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
19
Pipe schematic from manhole 18 0616 to 18 0615
MH: 18 0616MH: 18 0615downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 06166.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES15.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES19.2 ft. CM - Crack Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES25.7 ft. B - Broken, from 12 to 12 o'clock, within 8 inches of joint: YES27.4 ft. AOC - Drop Connection, Survey Ends - 18 061527.4 ft. FM - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: NO - AT DROP CONNECTION

Observation photos (5)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    6.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    15.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES

    19.2 ft. - Crack Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES

  • Broken, from 12 to 12 o'clock, within 8 inches of joint: YES

    25.7 ft. - Broken, from 12 to 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: NO - AT DROP CONNECTION

    27.4 ft. - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: NO - AT DROP CONNECTION

Observations (9)

DistanceCodeObservation
15.7FM
27.4AOC18 0615
6.4CM
0MWM
27.4FMAT DROP CONNECTION
0MWL
25.7B
0AMH18 0616
19.2CM

Properties (7)

additional_info
SC411608
custom_field_three
BROKEN PIPE
custom_field_two
1
customer
1
datetime
2020-06-15T01:33:40-07:00
documentation
PROPIPE
is_lateral_inspection
false