Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 29, 2020, 07:07 AM
  • 18 0430_18 0429 _05292020_001619.mp4

Date
05/29/2020
W/O
828932
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00675
PipeID
P14278
Time
12:07 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7715
Sewer Name
18 FLORENCE AVENUE TRUNK
City
SANTA FE SPRINGS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_828932_TV18097_MAY2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
18 0429
Downstream MH
18 0430
Dir. of Survey
Upstream
Length Surveyed
97.5 ft.
Total Length
97.5 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 18 0429 to 18 0430
MH: 18 0429MH: 18 0430upstream0 ft. MSA - Survey Abandoned - REVERSAL COMPLETED0 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish0 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish95.4 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - sludge95.4 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start97.4 ft. MWM - Water Mark, 15 %of cross sectional area97.5 ft. AMH - Downstream Manhole, Survey Begins - 18 042997.5 ft. MWL - Water Level, 5 %of cross sectional area97.5 ft. MGO - Reversal Inspection

Observation photos (3)

  • Deposits Settled Other,  15 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start - sludge

    2.1 ft. - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - sludge

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Survey Abandoned - REVERSAL COMPLETED

    97.5 ft. - Survey Abandoned - REVERSAL COMPLETED

Observations (9)

DistanceCodeObservation
97.5MSAREVERSAL COMPLETED
0AMH18 0429
2.1DSZsludge
97.5DSZ
0.1MWM
97.5SAP
2.1SAP
0MWL
0MGO

Properties (6)

additional_info
SC411372
custom_field_two
3
customer
LACSD
datetime
2020-05-29T00:07:13-07:00
documentation
PROPIPE
is_lateral_inspection
false