Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 13, 2020, 07:55 AM
  • 15 0186_15 0185 _05132020_010829.mp4

Date
05/13/2020
W/O
829157
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00605
PipeID
P12110
Time
12:55 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7660
Sewer Name
15 FERRIS ROAD TRUNK
City
EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
23
Purpose
Routine Assessment
Project
RFIR_WO_829157_TV15249_MAY2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 0185
Downstream MH
15 0186
Dir. of Survey
Upstream
Length Surveyed
275.8 ft.
Total Length
275.8 ft.
Structural Index
3
Structural Quick
3I00
Structural Rating
156
O&M Index
2
O&M Quick
2J00
O&M Rating
110
Overall Index
2
Overall Quick
Overall Rating
266
Pipe schematic from manhole 15 0185 to 15 0186
MH: 15 0185MH: 15 0186upstream0 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish0 ft. MSA - Survey Abandoned - REVERSAL COMPLETE AT DAMAGED LINK PIPE.1.7 ft. RPZ - Repair Other, within 8 inches of joint: YES - LINK PIPE2.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"37 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"44.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"75.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"101.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"108.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"127.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"154.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"173.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"200 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"214.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"225.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"260.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start271.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"273.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start275.8 ft. MWL - Water Level, 15 %of cross sectional area275.8 ft. MGO - General Observation - COCKROACHES IN MANHOLE275.8 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK275.8 ft. AMH - Downstream Manhole, Survey Begins - 15 0185275.8 ft. MWM - Water Mark, 25 %of cross sectional area

Observation photos (5)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    15.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Repair Other, within 8 inches of joint: YES - LINK PIPE

    274.1 ft. - Repair Other, within 8 inches of joint: YES - LINK PIPE

  • Survey Abandoned - REVERSAL COMPLETE AT DAMAGED LINK PIPE.

    275.8 ft. - Survey Abandoned - REVERSAL COMPLETE AT DAMAGED LINK PIPE.

Observations (24)

DistanceCodeObservation
148.1TFC
275.8CM
50.3TFC
121.6TFA
0MWL
200.6TFA
0MGOCOCKROACHES IN MANHOLE
273.5TFA
2DAGS
238.8TFC
275.8DAGS
75.8TFC
275.8MSAREVERSAL COMPLETE AT DAMAGED LINK PIPE.
102.5TFA
231.7TFC
0MGOCONNECTION AT MH 3 O'CLOCK
15.6CM
167TFC
274.1RPZLINK PIPE
61.2TFC
4TFA
0AMH15 0185
174.2TFA
0MWM

Properties (6)

additional_info
SC411251
custom_field_two
3
customer
LACSD
datetime
2020-05-13T00:55:10-07:00
documentation
PRO PIPE
is_lateral_inspection
false