Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 8, 2020, 09:55 AM
  • H 1195_H 0580 _05082020_030444.mp4

Date
05/08/2020
W/O
828927
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00188
PipeID
P21382
Time
2:55 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7656
Sewer Name
H JOINT OUTFALL H - UNIT 8E
City
BALDWIN PARK
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_828927_TV15172_MAY2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
H 1195
Downstream MH
H 0580
Dir. of Survey
Downstream
Length Surveyed
199.9 ft.
Total Length
199.9 ft.
Structural Index
4
Structural Quick
5G3G
Structural Rating
312
O&M Index
2
O&M Quick
412G
O&M Rating
82
Overall Index
3
Overall Quick
Overall Rating
394
Pipe schematic from manhole H 1195 to H 0580
MH: H 1195MH: H 0580downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 11950 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start197.7 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE197.7 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish197.7 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish197.7 ft. MGO - General Observation - COCKROACHES IN MANHOLE197.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish199.9 ft. AMH - Downstream Manhole, Survey Ends - H 0580, RUN LIST STATES MH AT 351'.

Observation photos (4)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    197.7 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (12)

DistanceCodeObservation
197.7MGOCONN @ MH 3 O'CLOCK/ACTIVE
2SAP
0AMHH 1195
197.7SAP
0MWM
199.9AMHH 0580, RUN LIST STATES MH AT 351'.
2DAGS
197.7SRV
2SRV
0MWL
197.7MGOCOCKROACHES IN MANHOLE
197.7DAGS

Properties (6)

additional_info
SC411247
custom_field_two
2
customer
LACSD
datetime
2020-05-08T02:55:34-07:00
documentation
PRO PIPE
is_lateral_inspection
false