Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 21, 2020, 07:23 AM
  • 18 0102_18 0101 _05212020_003528.mp4

Date
05/21/2020
W/O
828920
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00698
PipeID
P13922
Time
12:23 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7708
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
RFIR_WO_828920_TV18177_MAY2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0102
Downstream MH
18 0101
Dir. of Survey
Downstream
Length Surveyed
226.8 ft.
Total Length
226.8 ft.
Structural Index
3
Structural Quick
413H
Structural Rating
144
O&M Index
2
O&M Quick
2H00
O&M Rating
88
Overall Index
3
Overall Quick
Overall Rating
232
Pipe schematic from manhole 18 0102 to 18 0101
MH: 18 0102MH: 18 0101downstream0 ft. MGO - General Observation - ROACHES @ MH0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE0 ft. AMH - Upstream Manhole, Survey Begins - 18 01020 ft. MWL - Water Level, 20 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start57.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"60.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"99.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES109.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"112.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"120.4 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES160.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"164 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"209.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"213 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"220.6 ft. CM - Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES224 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish226.8 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE226.8 ft. AMH - Downstream Manhole, Survey Ends - 18 0101226.8 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/UNKNOWN226.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (4)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.9 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    99.5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    120.4 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

    220.6 ft. - Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

Observations (24)

DistanceCodeObservation
209.3TFC
164TFC
60.7TFC
224DAGS
0MGOROACHES @ MH
57.6TFC
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
2DAGS
213TFC
226.8MGOCONN @ MH 3 O'CLOCK/ACTIVE
0MWM
0MGOCONN @ MH 3 O'CLOCK/ACTIVE
99.5FM
226.8AMH18 0101
226.8MGOCONN @ MH 9 O'CLOCK/UNKNOWN
120.4CL
0AMH18 0102
226.8SAV
220.6CM
160.8TFC
109.6TFC
0MWL
2.9SAV
112.5TFC

Properties (6)

additional_info
SC411365
custom_field_two
3
customer
LACSD
datetime
2020-05-21T00:23:53-07:00
documentation
PROPIPE
is_lateral_inspection
false