Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 21, 2020, 07:44 AM
  • 18 0100_18 0099 _05212020_005115.mp4

Date
05/21/2020
W/O
828920
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00698
PipeID
P13920
Time
12:44 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7708
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
RFIR_WO_828920_TV18177_MAY2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0100
Downstream MH
18 0099
Dir. of Survey
Downstream
Length Surveyed
99.9 ft.
Total Length
100 ft.
Structural Index
3
Structural Quick
3G22
Structural Rating
124
O&M Index
2
O&M Quick
2C00
O&M Rating
38
Overall Index
3
Overall Quick
Overall Rating
162
Pipe schematic from manhole 18 0100 to 18 0099
MH: 18 0100MH: 18 0099downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 01000 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - ROACHES @ MH2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start7.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"10.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN18.7 ft. FC - Fracture Circumferential, from 06 to 09 o'clock, within 8 inches of joint: YES53.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"56.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"82.5 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES86.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"91.7 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES97 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish97 ft. MGO - General Observation - ROACHES @ MH97 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish100 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish100 ft. AMH - Downstream Manhole, Survey Ends - 18 0099

Observation photos (4)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.4 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Circumferential, from 06 to 09 o'clock, within 8 inches of joint: YES

    18.7 ft. - Fracture Circumferential, from 06 to 09 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    82.5 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    91.7 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (20)

DistanceCodeObservation
0AMH18 0100
2CM
82.5CL
2.4SAV
0MWL
100SAV
56.4TF
7.4TFC
91.7CM
0MWM
86.9TF
97DAGS
2DAGS
10.7TFOPEN
18.7FC
97MGOROACHES @ MH
100AMH18 0099
53.1TF
0MGOROACHES @ MH
97CM

Properties (6)

additional_info
SC411365
custom_field_two
3
customer
LACSD
datetime
2020-05-21T00:44:05-07:00
documentation
PROPIPE
is_lateral_inspection
false