Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 22, 2020, 06:47 AM
  • 18 0084_18 0083 _05222020_000146.mp4

Date
05/21/2020
W/O
828920
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00698
PipeID
P13903
Time
11:47 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7709
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_828920_TV18177_MAY2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0084
Downstream MH
18 0083
Dir. of Survey
Downstream
Length Surveyed
386.2 ft.
Total Length
386.2 ft.
Structural Index
3
Structural Quick
3]00
Structural Rating
450
O&M Index
2
O&M Quick
2N12
O&M Rating
154
Overall Index
3
Overall Quick
Overall Rating
604
Pipe schematic from manhole 18 0084 to 18 0083
MH: 18 0084MH: 18 0083downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 00840 ft. MGO - General Observation - ROACHES @ MH2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start3.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start11.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN14.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start85.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"89.1 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN157.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"237.6 ft. RFJ - Roots Fine Joint, from 10 to 02 o'clock, within 8 inches of joint: YES257.4 ft. RFJ - Roots Fine Joint, from 09 to 04 o'clock, within 8 inches of joint: YES277.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"344.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"384 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish386.2 ft. AMH - Downstream Manhole, Survey Ends - 18 0083386.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish386.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.8 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    14.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (19)

DistanceCodeObservation
89.1TFOPEN
3.8SAV
0MWM
85.2TFC
0MWL
237.6RFJ
257.4RFJ
384DAGS
0AMH18 0084
344.3TF
386.2AMH18 0083
14.3CM
386.2CM
0MGOROACHES @ MH
277.6TF
157.4TF
2DAGS
11.8TFOPEN
386.2SAV

Properties (6)

additional_info
SC411366
custom_field_two
3
customer
LACSD
datetime
2020-05-21T23:47:44-07:00
documentation
PROPIPE
is_lateral_inspection