- Date
- 05/22/2020
- W/O
- 828920
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00698
- PipeID
- P13902
- Time
- 12:02 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K7709
- Sewer Name
- 18 SANTA FE STREET TRUNK
- City
- WHITTIER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- RFIR_WO_828920_TV18177_MAY2020
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 18 0083
- Downstream MH
- 18 0082
- Dir. of Survey
- Downstream
- Length Surveyed
- 382.1 ft.
- Total Length
- 382.1 ft.
- Structural Index
- 3
- Structural Quick
- 3]00
- Structural Rating
- 453
- O&M Index
- 2
- O&M Quick
- 2N00
- O&M Rating
- 152
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 605
Pipe schematic from manhole 18 0083 to 18 0082 Observation photos (2)

3.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

6.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start