Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 26, 2020, 08:05 AM
  • 05 1845_05 1844_6262020_011615.mp4

Date
06/26/2020
W/O
0833487
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00494
PipeID
P07070
Time
1:05 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1459
Sewer Name
05 NORTH SLOPE CONNECTION TRUNK
City
PALO VERDES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
35
Purpose
Routine Assessment
Project
20200625MDM_NORTH_SLOPE_CONNECTION_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
05 1845
Downstream MH
05 1844
Dir. of Survey
Downstream
Length Surveyed
240.1 ft.
Total Length
240.1 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
2
O&M Quick
2111
O&M Rating
3
Overall Index
2
Overall Quick
Overall Rating
5
Pipe schematic from manhole 05 1845 to 05 1844
MH: 05 1845MH: 05 1844downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:10AM14.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open23.9 ft. MGO - General Observation - 18" VCP65 ft. MWLS - Water Level, Sag in pipe, 10 %of cross sectional area70.9 ft. TFD - Tap Factory Made Defective, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open-10% ROOTS70.9 ft. RFC - Roots Fine Connection, from 08 to 12 o'clock, within 8 inches of joint: YES - 3%240.1 ft. AMH - Downstream Manhole, Survey Ends - 1:25AM

Observation photos (1)

  • General Observation - 18" VCP

    23.9 ft. - General Observation - 18" VCP

Observations (9)

DistanceCodeObservation
70.9TFDOpen-10% ROOTS
23.9MGO18" VCP
14.3TFOpen
70.9RFC3%
65MWLS
240.1AMH1:25AM
0MWL
0MWM
0AMH1:10AM

Properties (6)

custom_field_three
VCP GOOD COND
custom_field_two
4
customer
LACSD
datetime
2020-06-26T01:05:13-07:00
documentation
MARTIN,OLIVER 111,SHADLER,BARR
is_lateral_inspection
false