Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 25, 2020, 10:22 AM
  • 05 1847_05 1846_6252020_033247.mp4

Date
06/25/2020
W/O
0833487
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00494
PipeID
P07072
Time
3:22 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1458
Sewer Name
05 NORTH SLOPE CONNECTION TRUNK
City
PALO VERDES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
35
Purpose
Routine Assessment
Project
20200625MDM_NORTH_SLOPE_CONNECTION_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
05 1847
Downstream MH
05 1846
Dir. of Survey
Downstream
Length Surveyed
246.3 ft.
Total Length
246.3 ft.
Structural Index
2
Structural Quick
3224
Structural Rating
14
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
14
Pipe schematic from manhole 05 1847 to 05 1846
MH: 05 1847MH: 05 1846downstream0 ft. AMH - Upstream Manhole, Survey Begins - 3:30AM0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area34.2 ft. MGO - General Observation - 18"VCP34.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open112.1 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open160.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open160.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H160.4 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - SLIGHT160.4 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SLIGHT160.9 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - H189.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H190.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open241.3 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - H246.3 ft. AMH - Downstream Manhole, Survey Ends - 4:10AM

Observation photos (1)

  • General Observation - 18"VCP

    34.2 ft. - General Observation - 18"VCP

Observations (15)

DistanceCodeObservation
241.3FCH
0AMH3:30AM
246.3AMH4:10AM
160.4TFOpen
0MWM
160.4FLH
189.7FLH
160.4FCSLIGHT
160.4FCSLIGHT
0MWL
112.1TFOpen
34.2MGO18"VCP
34.2TFOpen
160.9FCH
190.4TFOpen

Properties (6)

custom_field_three
FEW SLIGHT FRACTURES
custom_field_two
4
customer
LACSD
datetime
2020-06-25T03:22:28-07:00
documentation
MARTIN,SHADLER,BARR
is_lateral_inspection
false