Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 29, 2020, 10:05 AM
  • 05 1006_05 1005 _05292020_031718.mp4

Date
05/29/2020
W/O
828882
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00421
PipeID
P06238
Time
3:05 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7717
Sewer Name
05 AVIATION BOULEVARD TRUNK
City
REDONDO BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
16
Purpose
Routine Assessment
Project
RFIR_WO_828882_TV05252_MAY2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 1006
Downstream MH
05 1005
Dir. of Survey
Downstream
Length Surveyed
335.2 ft.
Total Length
335.2 ft.
Structural Index
4
Structural Quick
4131
Structural Rating
7
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole 05 1006 to 05 1005
MH: 05 1006MH: 05 1005downstream0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 05 10060 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area7.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start58.4 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"63.4 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES134.3 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"211.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"283.9 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"335.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish335.2 ft. AMH - Downstream Manhole, Survey Ends - 05 1005335.2 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    7.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    63.4 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (14)

DistanceCodeObservation
0MGOCONN @ MH 9 O'CLOCK/
335.2CM
0MGOCONN @ MH 3 O'CLOCK
283.9TFC
134.3TFC
0AMH05 1006
335.2AMH05 1005
58.4TFC
0MWM
211.3TF
63.4FM
0MWL
335.2MGOCONNECTION AT MH 9 O'CLOCK
7.4CM

Properties (6)

additional_info
SC411374
custom_field_two
3
customer
LACSD
datetime
2020-05-29T03:05:10-07:00
documentation
PROPIPE
is_lateral_inspection
false