- Date
- 06/17/2020
- W/O
- 0833508
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00616
- PipeID
- P12618
- Time
- 12:21 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1448
- Sewer Name
- 15 MONROVIA OUTFALL TRUNK
- City
- MONROVIA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 05
- Purpose
- Capital Improvement Program Assesment
- Project
- 20200617MDM_MONROVIA_OUTFALL_TRUNK
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 24 in.
- Upstream MH
- 15 0725
- Downstream MH
- 15 0724
- Dir. of Survey
- Downstream
- Length Surveyed
- 652.7 ft.
- Total Length
- 652.7 ft.
- Structural Index
- 4
- Structural Quick
- 4321
- Structural Rating
- 14
- O&M Index
- 2
- O&M Quick
- 2211
- O&M Rating
- 5
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 19
Pipe schematic from manhole 15 0725 to 15 0724 Observation photos (6)

2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

2 ft. - General Observation - MAG COAT 85% START

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

45.3 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

109.8 ft. - Vermin Cockroach, within 8 inches of joint: YES - 1,000,000

471.6 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG