- Date
- 06/18/2020
- W/O
- 0828894
- Weather
- Dry
- Operator/Surveyor
- SANTIAGO OBREGON
- Sewer ID
- Z00168
- PipeID
- P20083
- Time
- 11:23 AM
- Certificate
- U-1014-06022541
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1451
- Sewer Name
- H JOINT OUTFALL H - UNIT 2B
- City
- BELL GARDENS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 23
- Purpose
- Routine Assessment
- Project
- 20200618SHO_JOINT_OUTFALL_H_UNIT_2B
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 42 in.
- Upstream MH
- H 0185
- Downstream MH
- H 0184
- Dir. of Survey
- Downstream
- Length Surveyed
- 512.3 ft.
- Total Length
- 512.3 ft.
- Structural Index
- 3
- Structural Quick
- 3121
- Structural Rating
- 5
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 9
Pipe schematic from manhole H 0185 to H 0184 Observation photos (2)

12.3 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

12.3 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SPORADICALLY THROUGHOUT