- Date
- 05/27/2020
- W/O
- 828846
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00250
- PipeID
- P02690
- Time
- 10:30 PM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K7674
- Sewer Name
- 02 DOWNEY AVENUE EXTENSION TRUNK
- City
- PARAMOUNT
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 36
- Purpose
- Routine Assessment
- Project
- RFIR_WO_828846_TV02126_MAY2020
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- 02 0375
- Downstream MH
- 02 0374
- Dir. of Survey
- Downstream
- Length Surveyed
- 328.3 ft.
- Total Length
- 328.3 ft.
- Structural Index
- 3
- Structural Quick
- 3L00
- Structural Rating
- 192
- O&M Index
- 2
- O&M Quick
- 412L
- O&M Rating
- 136
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 328
Pipe schematic from manhole 02 0375 to 02 0374 Observation photos (4)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

5.8 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

100.4 ft. - Tap Break-In Intruding, at 10 o'clock, -, #v, within 8 inches of joint: NO, 6", 3"

328.3 ft. - General Observation - COCKROACHES IN MANHOLE