- Date
- 05/07/2020
- W/O
- 828762
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00779
- PipeID
- P15707
- Time
- 9:27 PM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K7654
- Sewer Name
- 21 PHILLIPS BOULEVARD TRUNK
- City
- POMONA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 21
- Page No.
- 19
- Purpose
- Routine Assessment
- Project
- WO_828762_TV21017_MAY2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 21 0498
- Downstream MH
- 21 0497
- Dir. of Survey
- Downstream
- Length Surveyed
- 487.3 ft.
- Total Length
- 487.3 ft.
- Structural Index
- 3
- Structural Quick
- 3R2R
- Structural Rating
- 485
- O&M Index
- 2
- O&M Quick
- 2R00
- O&M Rating
- 194
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 679
Pipe schematic from manhole 21 0498 to 21 0497 Observation photos (7)

0 ft. - General Observation - COCKROACHES IN MANHOLE

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

76.4 ft. - General Observation - MAG COATING THROUGHOUT

170.3 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

484.8 ft. - General Observation - COCKROACHES IN MANHOLE