- Date
- 05/12/2020
- W/O
- 824117
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00942
- PipeID
- P11197
- Time
- 11:42 PM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K7600
- Sewer Name
- H JOINT OUTFALL H - UNIT 9C
- City
- SAN DIMAS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 22
- Purpose
- Routine Assessment
- Project
- RFIR_WO_824117_TV22079_APR2020
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 20 in.
- Width
- 20 in.
- Upstream MH
- H 0789
- Downstream MH
- H 0788
- Dir. of Survey
- Downstream
- Length Surveyed
- 737.9 ft.
- Total Length
- 737.9 ft.
- Structural Index
- 2
- Structural Quick
- 3\2^
- Structural Rating
- 753
- O&M Index
- 3
- O&M Quick
- 3\2\
- O&M Rating
- 735
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 1488
Pipe schematic from manhole H 0789 to H 0788 Observation photos (3)

2.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.6 ft. - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start - SLUDGE

737.9 ft. - Survey Abandoned - CAMERA BLKD BY SLUDGE