- Date
- 05/01/2020
- W/O
- 824117
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00942
- PipeID
- P11176
- Time
- 1:30 AM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K7623
- Sewer Name
- H JOINT OUTFALL H - UNIT 9C
- City
- WEST COVINA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 31
- Purpose
- Routine Assessment
- Project
- RFIR_WO_824117_TV22079_APR2020
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 22 in.
- Width
- 22 in.
- Upstream MH
- H 0768
- Downstream MH
- H 0767
- Dir. of Survey
- Downstream
- Length Surveyed
- 975.4 ft.
- Total Length
- 975.4 ft.
- Structural Index
- 3
- Structural Quick
- 3f2f
- Structural Rating
- 970
- O&M Index
- 2
- O&M Quick
- 218
- O&M Rating
- 784
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 1754
Pipe schematic from manhole H 0768 to H 0767 Observation photos (3)

4.5 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

4.5 ft. - Deposits Settled Compacted, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start - SLUDGE

931.7 ft. - Alignment Right, 10 %, Start