- Date
- 05/05/2020
- W/O
- 828842
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00168
- PipeID
- P10635
- Time
- 11:18 PM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K7594
- Sewer Name
- H JOINT OUTFALL H - UNIT 2B
- City
- BELL GARDENS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 23
- Purpose
- Routine Assessment
- Project
- RFIR_WO_828842_TV02360_MAY2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 39 in.
- Width
- 39 in.
- Upstream MH
- H 0188
- Downstream MH
- H 0187
- Dir. of Survey
- Downstream
- Length Surveyed
- 467.8 ft.
- Total Length
- 467.8 ft.
- Structural Index
- 3
- Structural Quick
- 5R3R
- Structural Rating
- 930
- O&M Index
- 2
- O&M Quick
- 2R00
- O&M Rating
- 186
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 1116
Pipe schematic from manhole H 0188 to H 0187 Observation photos (2)

2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.3 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start