- Date
- 05/05/2020
- W/O
- 828833
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00188
- PipeID
- P10995
- Time
- 2:48 AM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K7651
- Sewer Name
- H JOINT OUTFALL H - UNIT 8E
- City
- BALDWIN PARK
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 19
- Purpose
- Routine Assessment
- Project
- WO_828833_TV15173_MAY2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 27 in.
- Width
- 27 in.
- Upstream MH
- H 0571
- Downstream MH
- H 0570
- Dir. of Survey
- Downstream
- Length Surveyed
- 302.2 ft.
- Total Length
- 302.2 ft.
- Structural Index
- 3
- Structural Quick
- 3J00
- Structural Rating
- 162
- O&M Index
- 2
- O&M Quick
- 4131
- O&M Rating
- 132
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 294
Pipe schematic from manhole H 0571 to H 0570 Observation photos (7)

0 ft. - General Observation - COCKROACHES IN MANHOLE

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

4.5 ft. - General Observation - MAG COATING THROUGHOUT

28.8 ft. - Roots Medium Connection, from 08 to 10 o'clock, 15 %, within 8 inches of joint: YES

28.8 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

93.7 ft. - Roots Fine Connection, from 01 to 03 o'clock, within 8 inches of joint: YES

302.2 ft. - General Observation - COCKROACHES IN MANHOLE