Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 30, 2020, 04:11 PM
  • H 0398_H 0397_04302020_093259.mp4

Date
04/30/2020
W/O
823965
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00177
PipeID
P10827
Time
9:11 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7586
Sewer Name
H JOINT OUTFALL H - UNIT 5A
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
01
Purpose
Routine Assessment
Project
RFIR_WO_823965_TV18073_APR2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
51 in.
Width
51 in.
Upstream MH
H 0398
Downstream MH
H 0397
Dir. of Survey
Downstream
Length Surveyed
380.2 ft.
Total Length
380.2 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole H 0398 to H 0397
MH: H 0398MH: H 0397downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 03980 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. MGO - General Observation - MAG COAT19.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6380.2 ft. AMH - Downstream Manhole, Survey Ends - H 0397380.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
19.3TF
0AMHH 0398
2.1MGOMAG COAT
2SAV
0MWM
380.2AMHH 0397
0MWL
0MGOCONNECTION AT MH 3 O'CLOCK
380.2SAV

Properties (6)

additional_info
SC411145
custom_field_two
3
customer
LACSD
datetime
2020-04-30T09:11:53-07:00
documentation
PROPIPE
is_lateral_inspection
false