Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 30, 2020, 04:33 PM
  • H 0397_H 0396 _04302020_093931.mp4

Date
04/30/2020
W/O
823965
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00177
PipeID
P10826
Time
9:33 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7586
Sewer Name
H JOINT OUTFALL H - UNIT 5A
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
01
Purpose
Routine Assessment
Project
RFIR_WO_823965_TV18073_APR2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
51 in.
Width
51 in.
Upstream MH
H 0397
Downstream MH
H 0396
Dir. of Survey
Downstream
Length Surveyed
172.1 ft.
Total Length
172.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole H 0397 to H 0396
MH: H 0397MH: H 0396downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 03970 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - MAG COAT2.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start172.1 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK172.1 ft. AMH - Downstream Manhole, Survey Ends - H 0396172.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.9 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
172.1MGOCONNECTION AT MH 9 O'CLOCK
172.1AMHH 0396
2.9SAV
0AMHH 0397
172.1SAV
0MWM
0MWL
0MGOMAG COAT

Properties (6)

additional_info
SC411145
custom_field_two
3
customer
LACSD
datetime
2020-04-30T09:33:30-07:00
documentation
PROPIPE
is_lateral_inspection
false