Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 27, 2020, 03:31 PM
  • H 0394_H 0393_04272020_072837.mp4

Date
04/27/2020
W/O
823965
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00177
PipeID
P10823
Time
8:31 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7583
Sewer Name
H JOINT OUTFALL H - UNIT 5A
City
WHITTIER
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
01
Purpose
Routine Assessment
Project
RFIR_WO_823965_TV18073_APR2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
60 in.
Width
60 in.
Upstream MH
H 0394
Downstream MH
H 0393
Dir. of Survey
Downstream
Length Surveyed
634.4 ft.
Total Length
634.4 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole H 0394 to H 0393
MH: H 0394MH: H 0393downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 03940 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK8.4 ft. MGO - General Observation - MAG COAT8.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start328.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"634.4 ft. AMH - Downstream Manhole, Survey Ends - H 0393634.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    8.4 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
0AMHH 0394
328.8TF
0MWL
634.4AMHH 0393
8.4MGOMAG COAT
634.4SAV
0MWM
0MGOCONNECTION AT MH 3 O'CLOCK
8.4SAV

Properties (6)

additional_info
SC411142
custom_field_two
3
customer
LACSD
datetime
2020-04-27T08:31:52-07:00
documentation
PROPIPE
is_lateral_inspection
false