Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 29, 2020, 02:16 PM
  • H 0389_H 0388 _04292020_074225.mp4

Date
04/29/2020
W/O
823965
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00177
PipeID
P10818
Time
7:16 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7585
Sewer Name
H JOINT OUTFALL H - UNIT 5A
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
03
Purpose
Routine Assessment
Project
RFIR_WO_823965_TV18073_APR2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
54 in.
Width
54 in.
Upstream MH
H 0389
Downstream MH
H 0388
Dir. of Survey
Downstream
Length Surveyed
648.3 ft.
Total Length
648.3 ft.
Structural Index
3
Structural Quick
3Y00
Structural Rating
387
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
387
Pipe schematic from manhole H 0389 to H 0388
MH: H 0389MH: H 0388downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 03892.1 ft. MGO - General Observation - MAG COATING ATTATCHED2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start39.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"648.2 ft. MGO - General Observation - CONNECTION IN MH, 9 O' CLOCK648.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish648.3 ft. AMH - Downstream Manhole, Survey Ends - H 0388

Observations (9)

DistanceCodeObservation
0MWL
0MWM
2.1MGOMAG COATING ATTATCHED
39.1TFA
648.2MGOCONNECTION IN MH, 9 O' CLOCK
2.1SAV
648.3AMHH 0388
0AMHH 0389
648.2SAV

Properties (6)

additional_info
SC411144
custom_field_two
3
customer
LACSD
datetime
2020-04-29T07:16:09-07:00
documentation
PROPIPE
is_lateral_inspection
false