Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 1, 2020, 07:56 AM
  • 05 1457_05 1456_512020_012231.mp4

Date
05/01/2020
W/O
0828780
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00438
PipeID
P06679
Time
12:56 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1409
Sewer Name
05 EL NIDO TRUNK
City
TORRANCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
22
Purpose
Routine Assessment
Project
20200428VMR_EL_NIDO_TRUNK
Material
NRCP
Shape
Circular
Height
21 in.
Upstream MH
05 1457
Downstream MH
05 1456
Dir. of Survey
Downstream
Length Surveyed
281.6 ft.
Total Length
281.6 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
7
Pipe schematic from manhole 05 1457 to 05 1456
MH: 05 1457MH: 05 1456downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01:25 am3.3 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - Moderate3.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, at 05 o'clock, , within 8 inches of joint: YES, Start3.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 09 o'clock, , within 8 inches of joint: YES, Start4.9 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"80.3 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4" - Open156 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 4"231.5 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"278.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 09 o'clock, , within 8 inches of joint: YES, Finish278.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, at 05 o'clock, , within 8 inches of joint: YES, Finish278.9 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish281.6 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 8"281.6 ft. AMH - Downstream Manhole, Survey Ends - 01:45 am

Observations (15)

DistanceCodeObservation
0MWM
80.3TFAOpen
3.3SAVModerate
0MWL
3.3DAGS
231.5TFA
4.9TFC
156TFC
0AMH01:25 am
278.9DAGS
281.6TFA
3.3DAGS
278.9DAGS
281.6AMH01:45 am
278.9SAV

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2020-05-01T00:56:00-07:00
documentation
REVELES, OLIVER III, CASTILLO, SKINNER
is_lateral_inspection
false