- Date
- 05/28/2020
- W/O
- 0818360
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00015
- PipeID
- P00141
- Time
- 3:47 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1432
- Sewer Name
- 08 MAIN STREET RELIEF TRUNK
- City
- CARSON
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 07
- Purpose
- Capital Improvement Program Assesment
- Project
- 20200528MDM_MAIN_STREET_TRUNK_RELIEF_TRUNK
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 39 in.
- Upstream MH
- 08 0555
- Downstream MH
- 08 0554
- Dir. of Survey
- Downstream
- Length Surveyed
- 470.9 ft.
- Total Length
- 470.9 ft.
- Structural Index
- 2
- Structural Quick
- 2400
- Structural Rating
- 8
- O&M Index
- 2
- O&M Quick
- 2200
- O&M Rating
- 4
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 12
Pipe schematic from manhole 08 0555 to 08 0554 Observation photos (5)

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE CONCRETE

8 ft. - General Observation - MAG COAT 30% START

86.7 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE

320.5 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - SLIGHT BLISTERING CONCRETE

393.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - SLIGHT PEELING CONCRETE