Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 30, 2020, 07:41 PM
  • E 0015_E 0014_04302020_130016.mp4

Date
04/30/2020
W/O
828776
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00027
PipeID
P07595
Time
12:41 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7587
Sewer Name
E JOINT OUTFALL E - UNIT 1
City
COMPTON
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
06
Purpose
Routine Assessment
Project
WO_828776_TV01087_APR2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
51 in.
Width
51 in.
Upstream MH
E 0015
Downstream MH
E 0014
Dir. of Survey
Downstream
Length Surveyed
596.4 ft.
Total Length
596.4 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole E 0015 to E 0014
MH: E 0015MH: E 0014downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - E 001536.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6", 6"186.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6", 6"247.2 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 6"490 ft. LFW - Lining Failure Wrinkled, at 03 o'clock, within 8 inches of joint: YES - WRINKLES ARE OBSERVED THROUGHOUT THE LINE596 ft. LFDE - Lining Failure Defective End, from 12 to 04 o'clock596.4 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK596.4 ft. AMH - Downstream Manhole, Survey Ends - E 0014

Observations (10)

DistanceCodeObservation
0MWL
186.7TFA
596.4MGOCONNECTION AT MH 9 O'CLOCK
596.4AMHE 0014
247.2TF
0MWM
490LFWWRINKLES ARE OBSERVED THROUGHOUT THE LINE
596LFDE
36.3TFA
0AMHE 0015

Properties (7)

additional_info
SC411146
custom_field_two
4
customer
LACSD
datetime
2020-04-30T12:41:41-07:00
documentation
PROPIPE
is_lateral_inspection
false
lining
CIPP