Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 1, 2020, 04:57 PM
  • E 0014_E 0013_05012020_102007.mp4

Date
05/01/2020
W/O
828776
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00027
PipeID
P07594
Time
9:57 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7589
Sewer Name
E JOINT OUTFALL E - UNIT 1
City
COMPTON
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
06
Purpose
Routine Assessment
Project
WO_828776_TV01087_APR2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
51 in.
Width
51 in.
Upstream MH
E 0014
Downstream MH
E 0013
Dir. of Survey
Downstream
Length Surveyed
467.9 ft.
Total Length
467.9 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole E 0014 to E 0013
MH: E 0014MH: E 0013downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - E 001431 ft. LFW - Lining Failure Wrinkled, from 08 to 12 o'clock, within 8 inches of joint: NO70 ft. LFZ - Lining Failure Other, at 10 o'clock, within 8 inches of joint: NO - POSISIBLE UNDERCUT ON CONNECTION70.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"416.6 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"467.9 ft. AMH - Downstream Manhole, Survey Ends - E 0013

Observations (8)

DistanceCodeObservation
70LFZPOSISIBLE UNDERCUT ON CONNECTION
70.8TF
0MWM
31LFW
0MWL
467.9AMHE 0013
0AMHE 0014
416.6TFA

Properties (7)

additional_info
SC411146
custom_field_two
4
customer
LACSD
datetime
2020-05-01T09:57:29-07:00
documentation
PROPIPE
is_lateral_inspection
false
lining
CIPP