Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 9, 2020, 07:35 AM
  • 05 1094_05 1093_04092020_005221.mp4

Date
04/09/2020
W/O
818458
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00488
PipeID
P06328
Time
12:35 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7559
Sewer Name
05 MONETA EXTENSION TRUNK, SECTION 1
City
GARDENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
18
Purpose
Routine Assessment
Project
RFIR_WO_818458_TV05328_MAR2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
05 1094
Downstream MH
05 1093
Dir. of Survey
Downstream
Length Surveyed
321.6 ft.
Total Length
321.6 ft.
Structural Index
2
Structural Quick
3223
Structural Rating
12
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
12
Pipe schematic from manhole 05 1094 to 05 1093
MH: 05 1094MH: 05 1093downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 10944.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start24.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"111.6 ft. FS - Fracture Spiral, from 01 to 04 o'clock, within 8 inches of joint: YES124.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"129 ft. FC - Fracture Circumferential, from 07 to 12 o'clock, within 8 inches of joint: YES214.9 ft. FC - Fracture Circumferential, from 10 to 05 o'clock, within 8 inches of joint: YES225.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"230.3 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES, Start321.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish321.6 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES, Finish321.6 ft. AMH - Downstream Manhole, Survey Ends - 05 1093

Observation photos (5)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Spiral, from 01 to 04 o'clock, within 8 inches of joint: YES

    111.6 ft. - Fracture Spiral, from 01 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 07 to 12 o'clock, within 8 inches of joint: YES

    129 ft. - Fracture Circumferential, from 07 to 12 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 10 to 05 o'clock, within 8 inches of joint: YES

    214.9 ft. - Fracture Circumferential, from 10 to 05 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES, Start

    230.3 ft. - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES, Start

Observations (14)

DistanceCodeObservation
111.6FS
321.5CM
0MWM
24.4TF
321.6FC
214.9FC
124.7TF
0MWL
129FC
321.6AMH05 1093
230.3FC
225.3TF
4.7CM
0AMH05 1094

Properties (6)

additional_info
SC411118
custom_field_two
3
customer
LACSD
datetime
2020-04-09T00:35:20-07:00
documentation
PROPIPE
is_lateral_inspection
false