Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 27, 2020, 08:34 AM
  • B 1097_B 1096 _04272020_020100.mp4

Date
04/27/2020
W/O
823875
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z01124
PipeID
P13722
Time
1:34 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7542
Sewer Name
B JOINT OUTFALL B - UNIT 6G
City
ALHAMBRA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_823875_TV02344_APR2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
36 in.
Width
36 in.
Upstream MH
B 1097
Downstream MH
B 1096
Dir. of Survey
Downstream
Length Surveyed
866 ft.
Total Length
866 ft.
Structural Index
3
Structural Quick
3a00
Structural Rating
516
O&M Index
2
O&M Quick
412b
O&M Rating
350
Overall Index
3
Overall Quick
Overall Rating
866
Pipe schematic from manhole B 1097 to B 1096
MH: B 1097MH: B 1096downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MGO - General Observation - ROACHES IN MH0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start0 ft. AMH - Upstream Manhole, Survey Begins - B 10972 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start221.5 ft. RPP - Repair Patch, from 01 to 05 o'clock, within 8 inches of joint: YES - PATCH332.5 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6", 6"620.8 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"648.4 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 10"736.1 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 10"832.3 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6", 6"863.7 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish863.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish866 ft. MGO - General Observation - ROACHES IN MH866 ft. AMH - Downstream Manhole, Survey Ends - B 1096

Observation photos (5)

  • General Observation - ROACHES IN MH

    0 ft. - General Observation - ROACHES IN MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    0 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Repair Patch, from 01 to 05 o'clock, within 8 inches of joint: YES - PATCH

    221.5 ft. - Repair Patch, from 01 to 05 o'clock, within 8 inches of joint: YES - PATCH

  • General Observation - ROACHES IN MH

    866 ft. - General Observation - ROACHES IN MH

Observations (17)

DistanceCodeObservation
0MWL
0MGOCONNECTION AT MH 3 O'CLOCK
620.8TB
648.4TFC
863.7SAP
832.3TB
221.5RPPPATCH
2SAP
0MGOROACHES IN MH
866MGOROACHES IN MH
736.1TFC
0MWM
0DAGS
0AMHB 1097
863.7DAGS
866AMHB 1096
332.5TB

Properties (6)

additional_info
SC411233
custom_field_two
3
customer
LACSD
datetime
2020-04-27T01:34:07-07:00
documentation
PRO PIPE
is_lateral_inspection
false