Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 21, 2020, 05:16 AM
  • B 0271 E_B 0270 _04202020_222139.mp4

Date
04/20/2020
W/O
823828
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00079
PipeID
P08752
Time
10:16 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7531
Sewer Name
B JOINT OUTFALL B - UNIT 1F
City
ROSEMEAD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
27
Purpose
Routine Assessment
Project
RFIR_WO_823828_TV15218_APR2020
Sewer Type
Siphon
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
B 0271 E
Downstream MH
B 0270
Dir. of Survey
Downstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole B 0271 E to B 0270
MH: B 0271 EMH: B 0270downstream0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. AMH - Upstream Manhole, Survey Begins - B 0271 E0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES2 ft. MSA - Survey Abandoned - VIEW OF DOWNLEG OF U/S EAST SIPHON.

Observation photos (3)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Survey Abandoned - VIEW OF DOWNLEG OF U/S EAST SIPHON.

    2 ft. - Survey Abandoned - VIEW OF DOWNLEG OF U/S EAST SIPHON.

Observations (6)

DistanceCodeObservation
0MGOCOCKROACHES IN MANHOLE
0AMHB 0271 E
0MWL
0MWM
2SSS
2MSAVIEW OF DOWNLEG OF U/S EAST SIPHON.

Properties (6)

additional_info
SC411222
custom_field_two
2
customer
LACSD
datetime
2020-04-20T22:16:29-07:00
documentation
PRO PIPE
is_lateral_inspection
false