Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 24, 2020, 04:13 AM
  • J 0067_J 0066_04232020_212442.mp4

Date
04/23/2020
W/O
823820
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00063
PipeID
P11646
Time
9:13 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7579
Sewer Name
J JOINT OUTFALL J - UNIT 2D
City
TORRANCE
Loc. details
Sidewalk
Location Code
F
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
32
Purpose
Routine Assessment
Project
RFIR_WO_823820_TV05340_APR2020
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
39 in.
Width
39 in.
Upstream MH
J 0067
Downstream MH
J 0066
Dir. of Survey
Downstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
3
Structural Quick
5131
Structural Rating
10
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
14
Pipe schematic from manhole J 0067 to J 0066
MH: J 0067MH: J 0066downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - J 00672 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES2.1 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES2.1 ft. MSA - Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH2.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

Observation photos (3)

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

    2.1 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH

    2.1 ft. - Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (8)

DistanceCodeObservation
0MWM
2.1SRV
2.1MSAVIEW OF D/S SIPHON FROM U/S MH
2SSS
0MGOCONNECTION AT MH 9 O'CLOCK
0MWL
2.1SAP
0AMHJ 0067

Properties (6)

additional_info
SC411138
custom_field_two
2
customer
LACSD
datetime
2020-04-23T21:13:24-07:00
documentation
PROPIPE
is_lateral_inspection
false