Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 24, 2020, 04:32 AM
  • J 0067_J 0066_04232020_213638.mp4

Date
04/23/2020
W/O
823820
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00063
PipeID
P11646
Time
9:32 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7579
Sewer Name
J JOINT OUTFALL J - UNIT 2D
City
TORRANCE
Loc. details
Sidewalk
Location Code
F
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
32
Purpose
Routine Assessment
Project
RFIR_WO_823820_TV05340_APR2020
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
39 in.
Width
39 in.
Upstream MH
J 0066
Downstream MH
J 0067
Dir. of Survey
Upstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole J 0066 to J 0067
MH: J 0066MH: J 0067upstream0 ft. MSA - Survey Abandoned - VIEW OF U/S SIPHON FROM D/S MH0 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES0.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES2.1 ft. AMH - Downstream Manhole, Survey Begins - J 00662.1 ft. MWL - Water Level, 40 %of cross sectional area2.1 ft. MWM - Water Mark, 45 %of cross sectional area

Observation photos (2)

  • Survey Abandoned - VIEW OF U/S SIPHON FROM D/S MH

    2.1 ft. - Survey Abandoned - VIEW OF U/S SIPHON FROM D/S MH

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (6)

DistanceCodeObservation
0AMHJ 0066
2.1MSAVIEW OF U/S SIPHON FROM D/S MH
0MWL
2SSS
2.1SAP
0MWM

Properties (6)

additional_info
SC411138
custom_field_two
2
customer
LACSD
datetime
2020-04-23T21:32:53-07:00
documentation
PROPIPE
is_lateral_inspection
false