Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 20, 2020, 11:10 AM
  • 01 0637_01 0636_5202020_041310.mp4

Date
05/20/2020
W/O
0829299
Weather
Dry
Operator/Surveyor
U-115-06022630
Sewer ID
Z00212
PipeID
P01133
Time
4:10 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1424
Sewer Name
01 MOUNTAIN VIEW-BELLE VERNON TRUNK
City
HUNTINGTON PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Routine Assessment
Project
20200519VMR_MOUNTAIN_VIEW_BELLE_VERNON_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
01 0637
Downstream MH
01 0636
Dir. of Survey
Downstream
Length Surveyed
379.7 ft.
Total Length
379.7 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 01 0637 to 01 0636
MH: 01 0637MH: 01 0636downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 04:13 AM2.1 ft. LFW - Lining Failure Wrinkled, from 09 to 03 o'clock, within 8 inches of joint: NO2.7 ft. LFBU - Lining Failure Bulges, at 02 o'clock, within 8 inches of joint: NO72 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 4"118.7 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 4" - Open175.4 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 4" - Open199 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 4" - Open224.9 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 4" - Open279.3 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 4" - Open354.5 ft. LFZ - Lining Failure Other, at 12 o'clock, within 8 inches of joint: NO - PATCH379.7 ft. AMH - Downstream Manhole, Survey Ends - 04:44 AM

Observation photos (1)

  • Lining Failure Wrinkled, from 09 to 03 o'clock, within 8 inches of joint: NO

    2.1 ft. - Lining Failure Wrinkled, from 09 to 03 o'clock, within 8 inches of joint: NO

Observations (13)

DistanceCodeObservation
279.3TBOpen
199TFOpen
2.1LFW
72TF
0MWL
224.9TFOpen
0MWM
175.4TFOpen
0AMH04:13 AM
118.7TFOpen
379.7AMH04:44 AM
354.5LFZPATCH
2.7LFBU

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2020-05-20T04:10:36-07:00
documentation
REVELES, OLIVER III, CASTILLO, SKINNER
is_lateral_inspection