- Date
- 04/22/2020
- W/O
- 823759
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00627
- PipeID
- P12153
- Time
- 1:48 AM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K7535
- Sewer Name
- 15 SAN JOSE CREEK TRUNK
- City
- CITY OF INDUSTRY
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 33
- Purpose
- Routine Assessment
- Project
- RFIR_WO_823759_TV15207_APR2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 36 in.
- Width
- 36 in.
- Upstream MH
- 15 0232
- Downstream MH
- 15 0230
- Dir. of Survey
- Downstream
- Length Surveyed
- 653 ft.
- Total Length
- 653 ft.
- Structural Index
- 3
- Structural Quick
- 5Y3Y
- Structural Rating
- 1334
- O&M Index
- 2
- O&M Quick
- 2k00
- O&M Rating
- 444
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 1778
Pipe schematic from manhole 15 0232 to 15 0230 Observation photos (4)

2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

171.3 ft. - General Observation - ABANDONED MH